List of OPC UA Event Types

The SmartController node can publish OPC UA events in response to a bat activity alarm raising or clearing, or in response to various system states that could indicate an error.

These events are fully specified in the files located at /usr/local/share/smart/opcua.

Table 1. Bat Alarm OPC UA Events
Event Name Description
BatPassRaiseAlarmEventType Generated when a bat pass alarm is raised.
BatPassClearAlarmEventType Generated when a bat pass alarm is cleared.
BatPulseRaiseAlarmEventType Generated when a bat pulse alarm is raised.
BatPulseClearAlarmEventType Generated when a bat pulse alarm is cleared.
Table 2. SMART System OPC UA EventsThese alerts must be enabled in the SMART Control Panel's Maintenance tab, under Email Alerts, in order to be published via OPC UA.
Event Name Event Message Description
SystemRebootEventType System Reboot Alert Triggered The SMART System has detected a reboot since the last reboot time stamp.
SystemDiskFullEventType Disk Full Alert Triggered The SMART System's internal disk space has fallen below the threshold defined on the Maintenance tab, under Email Alerts.
SystemMicMissingEventType Microphone Missing Alert Triggered for microphone prefix The SMART System has lost connection with the specified microphone.
SystemPrimaryMicCalibrationEventType Primary Microphone Calibration Alert Triggered for microphone prefix The calibration result for the primary element of the specified microphone has fallen below the specified threshold on the Maintenance tab.
SystemBackupMicCalibrationEventType Backup Microphone Calibration Alert Triggered for microphone prefix The calibration result for the backup element of the specified microphone has fallen below the specified threshold on the Maintenance tab.
SystemMicFailedEventType Microphone Failure Alert Triggered for microphone prefix The calibration results for both the primary and backup elements of the specified microphone have fallen below the specified threshold on the Maintenance tab.